Program memory:24;
2 RS-485 ports, within2 standard PPI port;
Boolean execution speed:0.08µsa
Program memory:24;
2 RS-485 ports, within2 standard PPI port;
Boolean execution speed:0.08µsa
Model No.
CPU 226-2R AC/DC/RELAY
Order No.
UN 216-2BD23-0XB0
Physical characteristic |
|
Dimensions(W x H x D)(mm) |
196×80×62 |
Power consume |
17W |
Memory |
|
Program memory size |
24K |
Data memory |
10K |
I/O |
|
Local digital inputs |
24 inputs |
Local digital outputs |
16 outputs |
Digital I/O image size |
256(128 inputs/128 outputs) |
Analog I/O image size |
64(32 inputs/32 outputs) |
expansion modules allowed (Max) |
7 modules |
intelligent modules allowed (Max) |
7 modules |
Pulse catch inputs |
24 |
High-speed counters |
6 counters total |
Single phase |
6 at 30KHz |
Two phase |
4 at 20KHz |
Pulse outputs |
- |
General |
|
Timer |
Total number:512(1ms:8;10ms:32;100ms:472) |
Counters |
512 |
Internal memory bits stored on power down |
512 |
Time interrupts |
2 with1ms resolution |
Edge interrupts |
4 up and/or 4 down |
Analog adjustment |
2 with 8 bit resolution |
Boolean execution speed |
0.08µs per instruction |
Real Time Clock |
Built-in |
Communications Built-in |
|
Ports |
3 RS-485 ports, within2 standard PPI port |
PPI Baud Rates |
9.6,19.2 and 187.5 Kbaud |
Freeport Baud Rates |
1.2kbaud to 115.2Kbps |
Max. cable length per segment |
With isolated repeater:1000 m up to 187.5kbaud, 1200 mup to 38.4kbaud Without isolated repeater: 50 m |
Max. number of stations |
32 per segment, 126 per network |
Max. number of masters |
32 |
Peer to peer(PPI Master Mode) |
Yes |
Power |
|
Input voltage |
85 to 264 V AC(47 to 63Hz) |
Input current |
60/30mA while CPU only at 120/240V AC |
200/100Ma while Max. load at 120/240V AC |
|
Inrush current |
20A at 264 V AC |
Isolation(field to logic) |
1500 V AC |
Hold up time(loss of power) |
10ms at 120/240 V AC |
Sensor voltage |
20.4 to 28.8 V DC |
Current limit |
1.5A peak,thermal limit non-destructive |
Ripple noise (sensor to logic) |
Less than 1 V peak-to-peak |
Isolation (sensor to logic) |
Not isolated |
CPU Digital Input Specifications |
|
Built-in digital inputs |
24 |
Input type |
PNP/NPN |
Rated voltage |
24 V DC at 4mA |
Max. continuous permissible voltage |
30V DC |
Surge voltage |
35 V DC,0.5s |
Logic “1” voltage range |
15 to 30 V DC |
Logic “0” voltage range |
0 to 5 V DC |
Input delay |
Selectable (0.2 to 12.8ms) |
Connection of 2-wire proximity sensor (Bero) Premissible leakage current (Max.) |
1mA |
Isolation (field to logic) |
Yes |
Optical galvanic |
500 V AC for 1minute |
Isolation groups |
Refer to Wiring diagram |
High Speed Counter (HSC) input rate |
|
HSC logic level 1(15 TO 30 V DC) |
20K Hz (Single phase), 10K Hz (Tow phase) |
HSC logic level 1(15 TO 26 V DC) |
30K Hz (Single phase), 20K Hz (Tow phase), |
Inputs on simultaneously |
all |
Cable length Max. |
|
Shielded |
500m normal inputs, 50m HSC inputs |
unshielded |
300m normal inputs |
CPU Digital Output Specifications |
|
Built-in outputs |
16 outputs |
Output type |
Dry contact |
Rated voltage |
24 V DC or 250 V AC |
Voltage range |
5 to 30 V DC or 5 to 250 V AC |
Surge current (Max.) |
5A for 4s at 10% duty cycle |
Logic “1” (Min) |
- |
Logic “0” (Max) |
- |
Rated current per point(Max.) |
2.0A |
Rated current per common(Max) |
10A |
Leakage current (Max) |
- |
Lamp load (Max) |
30W DC;200W AC |
Inductive clamp voltage |
|
On State resistance (contact) |
0.2Ω(max. when new) |
Isolation |
|
Optical (galvanic, field to logic) |
- |
logic to contact |
1500 V AC for 1 minute |
Resistance (logic to contact) |
100MΩ |
Isolation groups |
Refer to wiring diagram |
Delay(Max) |
|
Off to on |
- |
On to off |
- |
Switching |
10ms |
Pulse frequency (Max.) |
1Hz |
Lifetime mechanical cycles |
10,000,000 (no load) |
Lifetime contacts |
100,000 (rated load) |
Outputs on simultaneously |
All at 60℃ (horizontal) |
All at 50℃ (Vertical) |
|
Connecting two outputs in parallel |
No |
Cable Length (Shielded) |
500m |
Cable Length (unshielded) |
150m |